Guide to the Canadian Electrical Code, Part 1 — Instalment 13  - Electrical Industry News Week (2024)

May 3 2016

William (Bill) Burr

In this article: CE code Section 20 — Locations in which corrosive liquids, vapours, or excessive moisture are likely to be present. The code is a comprehensive document. Sometimes it can seem daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook, but will provide some help in navigating the code.

General

Section 22 amends or supplements the general requirements of the code. It provides specific rules for locations classified as Category 1 (moisture) or Category 2 (corrosive) environments that are sufficient enough to interfere with the normal operation of electrical equipment.

A Category 1 location is defined as one where moisture in the form of vapour or liquid is present. The moisture can be caused by condensation, dripping or splashing of liquid, or other means. A Category 2 location is defined as one where corrosive liquids or vapours are likely to be present. Where neither Category is mentioned in a rule in this section, then the rule applies to both categories. Appendix B contains examples of Category 1 and 2 occupancies.

Equipment

As per rule 22-100, only equipment that is essential to the process being carried out in that area may be located in a Category 1 or 2 location. Service equipment, motors, panelboards, switchboards and similar equipment need to be installed outside the category area. This includes any enclosures containing moulded case circuit breakers in a Category 2 location unless they have been approved and marked as suitable for that application, because internal corrosion can occur.

Rules 22-102 (1) to (6) outline the types of construction required of equipment to be installed in the various moist or corrosive atmospheres. This information is marked on the equipment if not self-evident.

Rules 22-104 to 22-108 specify requirements for pendent lamp holders, luminaires, receptacles, plugs, and portable cords to be installed or used in Category 1 or Category 2 locations.

Wiring

Rule 22-200 provides the requirements for wiring in Category 1 locations. Generally conductors must be selected in accordance with rule 4-008(1) and table 19. Note that NM cable must be NMU or NMWU, MI cable must be spaced 6mm from any wall at supports, and aluminum conductors must have joints adequately sealed against moisture.

Rule 22-202 provides the requirements for wiring in Category 2 locations. All conductors must have protection from corrosion. NMW and NMWU cable is permitted. Raceways, conductors and cables may only be used as permitted by Table 19. MI, alu-sheathed and copper-sheathed cable must be suitably corrosion protected. Any termination or joint of aluminum conductors must be adequately sealed against ingress of corrosive liquids or vapours.

Rule 22-204 outlines the appropriate wiring methods in buildings housing livestock or poultry. Again generally, these are wet or damp locations and all wiring must be selected in accordance with rule 4-008(1), with consideration given to adequate ventilation for a damp location. NMW or NMWU cable may be used, but aluminum conductors may not, and NMS cable must be provided with mechanical protection against damage by rodents.

Rule 22-206 deals with wiring in curling and skating rinks. Generally, lighting areas are subject to condensation so wiring must be selected in accordance with Rule 4-008(1) and Table 19 for wet locations. Other areas may be wired in accordance with Section 12 observing any moisture conditions. Areas with adequate mechanical ventilation (at least three changes per hour) may be considered dry locations.

Drainage, sealing, and exclusion of moisture and corrosive vapour

Rules 22-300 and 22-302 specify methods for excluding moisture and corrosive vapours from entering conduit, cables, equipment or locations through the use of approved fittings, drip loops, adequate drainage, sealing, and orientation.

Circuit control

Rule 22-400 requires that each circuit in a Category 1 or 2 location must be capable of being de-energized from outside the location.

Materials

Rule 22-500 specifies that all metal materials including conduit, enclosures, and even every nut bolt and screw must be corrosion protected or resistant to the specific corrosive environment.

Bonding

Rule 22-600 requires all non-current carrying metal parts of equipment to be bonded to ground as per Section 10.

Sewage lift and treatment plants

Rules 22-700 to 22-710 apply to installations in sewage lift, pumping stations and treatment plants where moisture, corrosion, explosions, fire and atmospheric poisoning can occur. Note that the rules of Section 18 apply to associated methane gas generating facilities.

Rule 22-702 outlines some special terminology used in this subsection to define continuous positive pressure ventilation, dry well, suitably cut off, and wet well.

Rule 22-704 provides guidelines for the classification of these types of areas that may be both Category 1 or 2, and hazardous locations under Section 18. Reference material for hazardous area classification can be found in NFPA 820. Appendix B also has some notes regarding safety issues in these types of facilities.

Rule 22-706 specifies that wiring methods in these types of areas shall be in accordance with Rules 22-200, 22-202 or Section 18 depending on the location classification. Note that there are some restrictions, conditions and special handling for metal conduit, tubing, armoured cable, mineral-insulated cable, aluminum sheathed cable, and copper-sheathed cable.

Electrical equipment

Rule 22-708 specifies that electrical equipment in these types of areas shall be in accordance with the other applicable sections of the code or Section 18, depending on the location classification. Note that there are some restrictions, conditions and special handling for receptacles, lighting switches, unit emergency lighting equipment, emergency lighting control units, heating equipment, motors, and any electrical equipment in a wet well. Also note in sub-rule 22-708(4) that ventilation fans shall not be located in a wet well. One other significant sub-rule, 22-708(5), requires that areas provided with continuous positive ventilation must be interlocked to de-energize all electrical equipment if the ventilating equipment becomes inoperative, unless the electrical equipment in that area is approved for a Class 1 hazardous location.

Rule 22-710 requires all structural steel below ground, in contact with earth to be bonded to the system ground.

In the next instalment we will be discussing Section 24 — Patient care areas.

* The source for this series of articles is the Canadian Electrical Code, Part I, published by CSA

Read the rest of the instalments in the series:
Part 1: Guide to the CE Code, Part I – A Roadmap (Installment 1 in a Series)
Part 2:
A Road Map to the CE Code, Part I – Installment 2
Part 3: Guide to the Canadian Electrical Code, Part I – Installment 3
Part 4: A Road Map to the CE Code, Part 1 – Installment 4
Part 5: Guide to the Canadian Electrical Code, Part I — Installment 5
Part 6: Guide to the Canadian Electrical Code, Part I — Installment 6
Part 7: Guide to the Canadian Electrical Code, Part I — Installment 7
Part 8: Guide to the Canadian Electrical Code, Part I — Installment 8
Part 9:
Guide to the Canadian Electrical Code, Part I — Installment 9Part 10: Guide to the Canadian Electrical Code, Part 1 – Installment 10
Part 11: Guide to the Canadian Electrical Code, Part 1 – Installment 11
Part 12: Guide to the Canadian Electrical Code, Part 1 — Instalment 12
Part 13: Guide to the Canadian Electrical Code, Part 1 — Instalment 13 
Part 14: Guide to the Canadian Electrical Code, Part 1 — Instalment 14
Part 15: Guide to the Canadian Electrical Code, Part I — Instalment 15

William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

Guide to the Canadian Electrical Code, Part 1 — Instalment 13  - Electrical Industry News Week (2024)

FAQs

What is the Canadian Electrical Code Part 1? ›

The Canadian Electrical Code, Part I (the Code) establishes guidelines and requirements necessary to reduce risks of electric shock, fires, and other electrical hazards.

What is the latest Canadian electrical code book? ›

The current edition of the CEC was released in January 2021; the 26th edition will be released in 2024.

What is the Canadian Electrical Code 2024 update? ›

The 2024 Canadian Electrical Code, Part I (twenty-sixth edition) was published on March 4, 2024 and is scheduled to come into force on April 1, 2025 throughout the Province of Alberta. Alberta Municipal Affairs. Public Safety Division.

What are the changes in 2024 CEC? ›

A new rapid shutdown method is being permitted in 2024, as well as some adjustments to technical requirements for renewable energy systems. This includes changes in placement of inverters and disconnects, which can simplify electrical systems and make them easier to manage.

What countries use the Canadian Electrical Code? ›

Canadian Electrical Code published by the CSA is used in Canada (see Electrical wiring in North America). British Standard BS 7671 is the set of regulations for electrical wiring in the United Kingdom. Australian/New Zealand Standard AS/NZS 3000:2007 Wiring Rules is used in Australia and New Zealand.

What is the acronym for the Canadian Electrical Code? ›

CEC - Canadian Electrical Code.

What is the difference between Canadian Electrical Code Part 1 and 2? ›

The Canadian Electrical Code is published in several parts: Part I is the safety standard for electrical installations. Part II is a collection of individual standards for the evaluation of electrical equipment or installations.

What is the most current electrical code? ›

The NEC is approved as an American national standard by the American National Standards Institute (ANSI). It is formally identified as ANSI/NFPA 70. First published in 1897, the NEC is updated and published every three years, with the 2023 edition being the most current.

What is the latest electrical code? ›

NFPA 70, National Electrical Code (NEC) (2023)

What is the standard 3 phase voltage in Canada? ›

In Canada, three-phase power is distributed in various voltages (120/208v, 240v, 480v, and 347/600v) at 60Hz. Three-phase electrical is a high-power version of the single-phase alternating current used in our homes. It is used in electricity generation, transmission, and distribution.

Is it 110v in Canada? ›

In Canada and Quebec, and in fact everywhere in North America, the standard voltage is 120 V (with a standard frequency of 60 Hz) rather than the 220 volts used in Europe. However, don't be suprised if you hear or read 110 V.

What is Part 2 of the Canadian Electrical Code? ›

The individual Standards of the Canadian Electrical Code, Part II, provide definitions and specify construction, marking, and test requirements for a single class or closely allied group of electrical equipment.

Will there be a CEC only draw in 2024? ›

Is There Going to Be a CEC Draw in 2024? The next draw will most likely be another all programs draw, PNP draw, or priority occupations draw as that is what we have been seeing since July 2022. The last CEC only draw occurred on September 14, 2021.

What is the theme for CEC 2024? ›

Incorporate this year's theme, “Accessibility for All,” in your design and get the word out to your school about Exceptional Children's Week. Snap a picture of your door and use the hashtag #ECW2024. The Council for Exceptional Children will share it on our social media.

Where is CEC 2025? ›

Baltimore, MD

What is the difference between the Canadian Electrical Code Part 1 and Part 2? ›

The Canadian Electrical Code is published in several parts: Part I is the safety standard for electrical installations. Part II is a collection of individual standards for the evaluation of electrical equipment or installations.

What is the CE Code Part 2? ›

The objective of Standards issued as part of the Canadian Electrical Code, Part II, is to give consideration to the prevention of injury to persons and damage to property through proper design, good construction, and high quality of work.

Why does Canada use +1? ›

This is easy. Telephone System Network Code 1 is not for a specific country but for a geographic region: North America. It includes primarily the United States and Canada, the original Bell System, as well as much of the Caribbean Sea.

Top Articles
Latest Posts
Article information

Author: Rev. Porsche Oberbrunner

Last Updated:

Views: 6469

Rating: 4.2 / 5 (53 voted)

Reviews: 84% of readers found this page helpful

Author information

Name: Rev. Porsche Oberbrunner

Birthday: 1994-06-25

Address: Suite 153 582 Lubowitz Walks, Port Alfredoborough, IN 72879-2838

Phone: +128413562823324

Job: IT Strategist

Hobby: Video gaming, Basketball, Web surfing, Book restoration, Jogging, Shooting, Fishing

Introduction: My name is Rev. Porsche Oberbrunner, I am a zany, graceful, talented, witty, determined, shiny, enchanting person who loves writing and wants to share my knowledge and understanding with you.