X-ray detection of ingested non-metallic foreign bodies (2024)

  • Journal List
  • World J Clin Pediatr
  • v.3(2); 2014 May 8
  • PMC4173203

As a library, NLM provides access to scientific literature. Inclusion in an NLM database does not imply endorsem*nt of, or agreement with, the contents by NLM or the National Institutes of Health.
Learn more: PMC Disclaimer | PMC Copyright Notice

X-ray detection of ingested non-metallic foreign bodies (1)

Link to Publisher's site

World J Clin Pediatr. 2014 May 8; 3(2): 14–18.

Published online 2014 May 8. doi:10.5409/wjcp.v3.i2.14

PMCID: PMC4173203

PMID: 25254180

Miguel Saps, John M Rosen, and Jacob Ecanow

Author information Article notes Copyright and License information PMC Disclaimer

Abstract

AIM: To determine the utility of X-ray in identifying non-metallic foreign body (FB) and assess inter-radiologist agreement in identifying non-metal FB.

METHODS: Focus groups of nurses, fellows, and attending physicians were conducted to determine commonly ingested objects suitable for inclusion. Twelve potentially ingested objects (clay, plastic bead, crayon, plastic ring, plastic army figure, glass bead, paperclip, drywall anchor, eraser, Lego™, plastic triangle toy, and barrette) were embedded in a gelatin slab placed on top of a water-equivalent phantom to simulate density of a child’s abdomen. The items were selected due to wide availability and appropriate size for accidental pediatric ingestion. Plain radiography of the embedded FBs was obtained. Five experienced radiologists blinded to number and types of objects were asked to identify the FBs. The radiologist was first asked to count the number of items that were visible then to identify the shape of each item and describe it to a study investigator who recorded all responses. Overall inter-rater reliability was analyzed using percent agreement and κ coefficient. We calculated P value to assess the probability of error involved in accepting the κ value.

RESULTS: Fourteen objects were radiographed including 12 original objects and 2 duplicates. The model’s validity was supported by clear identification of a radiolucent paperclip as a positive control, and lack of identification of plastic beads (negative control) despite repeated inclusion. Each radiologist identified 7-9 of the 14 objects (mean 8, 67%). Six unique objects (50%) were identified by all radiologists and four unique objects (33%) were not identified by any radiologist (plastic bead, Lego™, plastic triangle toy, and barrette). Identification of objects that were not present, false-positives, occurred 1-2 times per radiologist (mean 1.4). An additional 17% of unique objects were identified by less than half of the radiologists. Agreement between radiologists was considered almost perfect (kappa 0.86 ± 0.08, P < 0.0001).

CONCLUSION: We demonstrate potential non-identification of commonly ingested non-metal FBs in children. A registry for radiographic visibility of ingested objects should be created to improve clinical decision-making.

Keywords: Foreign bodies, X-rays, Pediatrics, Radiographic phantom, Diagnostic imaging

Core tip: Foreign body (FB) ingestion is very common in children and results in numerous visits for acute medical evaluation. X-ray identification of FB location and retention is used to guide management decisions including performance of additional imaging studies or FB retrieval. We investigated whether non-metal FB were visible on X-ray using a radiographic phantom. Our results show that expert radiologists are potentially unable to identify ingested non-metal foreign bodies. Creation of a database to catalogue X-ray characteristics of ingested non-metal objects would enable clinicians to improve quality of care by reduction of false-negative tests and prevention of unnecessary procedures.

INTRODUCTION

Foreign body (FB) ingestion in children was reported to United States poison control approximately 100000 times in 2010[1]. In children, the ingestion of FB is frequently not witnessed[2]. Unwitnessed FB ingestion poses a diagnostic challenge with important therapeutic implications[3,4]. Children are often too young or frightened to provide a reliable history. Children can remain asymptomatic despite ingestion of a potentially harmful FB. Even in the asymptomatic child, retention of an ingested FB may necessitate removal depending on type, location, or size. To solve this diagnostic and therapeutic challenge, physicians usually obtain X-ray studies (XR)[5]. XR is instrumental in cases of metal objects, however its utility is limited in cases of non-metal objects of unknown visibility. Despite limitations, XR is widely recommended as an initial diagnostic tool due to disadvantages of other imaging techniques (magnetic resonance imaging, computed tomography, and ultrasound) including cost, radiation exposure, and expertise/equipment required for performance and interpretation.

Although button batteries[6] and magnets[7] appropriately receive attention in the media and scientific literature because of harmful, sometimes fatal, ingestions, other objects also present significant risks. Case reports identify ingested non-metal materials including a plastic toy[8], pencil[9], tape[10], bottle cap diaphragm[11], ballpoint pen[12,13], toothbrush[14], eel vertebrae[15], twig[16] and other unusual objects[17,18] that may not be readily identifiable with routine XR. Ingestion of plastic toys can lead to intestinal obstruction[19] or other toxic effects of chronic retention due to plastic constituents[20]. Intestinal perforation also may result from ingestion of non-metal objects[21,22].

Confronted with the uncertainty of a possible FB, providers cannot make an informed and efficient decision. The provider may opt to rely on an XR result that provides false reassurance and potentially leads to otherwise preventable morbidity. Alternatively, the practitioner may distrust XR results and perform unnecessary diagnostic tests (i.e., endoscopy) with increased risk to the child. Instruction of parents to screen or strain the child’s stools for FB passage is inconvenient and may raise parental and child anxiety.

Despite high frequency of FB ingestion and importance of diagnostic radiography in guiding therapy, there are only case reports describing ability of XR to detect specific non-metallic FBs. Increased understanding of XR utility in diagnosis of non-metallic FBs is an initial step to improve clinical care. We conducted a study assessing non-metallic FB identification by XR.

MATERIALS AND METHODS

The primary aims of our descriptive study were to assess the ability of radiologists to detect non-metallic FBs through radiography and to determine the inter-rater agreement of detection. A secondary aim of our study was to create an easily reproducible model to assess visibility of ingested FB in children. Phantoms are frequently used for calibration and testing of imaging devices in radiology departments. For the purpose of this study we custom designed a water-equivalent phantom (WEP) to model the density of the child’s body. WEPs are composite materials that allow simulation and testing of radiographic techniques without human radiation exposure. To encase foreign bodies, a 2 cm thick gelatin-in-water mold was prepared by dissolving 28 g of gelatin in 1 quart of tap water (Knox Gelatin, Kraft Foods, Inc., Tarrytown, NY). The gelatin slab was placed on top of a standard WEP (Gammex Solid Water, Laco, Inc., Chesterland, OH) to create a composite (gelatin/WEP) phantom.

Twelve unique items, some with “choking hazard” warnings, and two copies of one item were encased in the gelatin slab (clay, plastic bead, crayon, plastic ring, plastic army figure, glass bead, paperclip, drywall anchor, eraser, Lego™, plastic triangle toy, and barrette). Potential items for inclusion were determined by conducting focus groups with nurses, gastroenterology fellows, and attending physicians. The items included were selected due to wide availability and appropriate size for accidental pediatric ingestion. Copies of one item, a plastic bead, were used to evaluate reliability of our model. A metallic paperclip was used as a positive control. The slab with encased objects was placed on an 18 cm thick WEP to create a 20 cm thick composite phantom representative of a 20 cm thick child. A single XR was obtained of the composite phantom with encased objects (Axiom Multix M, Siemens United States Corp., Washington, DC, United States, 70 kVP, 39 mAs, phototimer technique, table-top Bucky grid).

Five board certified radiologists, each with ten years or greater experience, and blinded to the number and identity of the items in the gelatin slab, were shown a single radiograph. The radiologist was first asked to count the number of items that were visible on the radiographic image. After recording the number of items identified, each radiologist was asked to identify the shape of each item and describe it to a study investigator who recorded all responses.

Statistical analysis

Overall inter-rater reliability was analyzed using percent agreement and κ coefficient. κ coefficient values < 0 indicate poor, 0-0.2 slight, 0.21-0.4 fair, 0.41-0.6 moderate, 0.61-0.8 substantial, and 0.81-1 almost perfect agreement, respectively. We calculated P value to assess the probability of error involved in accepting the κ value. This study was performed without the use of human or animal subjects.

RESULTS

Fourteen objects had color photographs taken before and after embedding in gelatin, and plain X-ray taken after embedding (Figure ​(Figure1).1). Each radiologist identified 7-9 of the 14 objects (mean 8, 67%). Six unique objects (50%) were identified by all radiologists and four unique objects (33%) were not identified by any radiologist (round plastic bead, Lego™, pink barrette, and purple triangle). Identification of objects that were not present, false-positives, occurred 1-2 times per radiologist (mean 1.4). An additional 17% of unique objects were identified by less than half of the radiologists. Agreement between radiologists was considered almost perfect (kappa 0.86 ± 0.08, P < 0.0001) (Table ​(Table11).

Table 1

Summary of object detection by radiologists

No.Rad 1Rad 2Rad 3Rad 4Rad 5Object
1+++++Army figure
2+++++Clay lump
3+++++Crayon
4+++++Eraser
5+++++Glass diamond bead
6+++++Paperclip
7-+--+Ring
8+----Drywall anchor
9-----Lego
10-----Pink barrette
11-----Plastic bead
12-----Plastic bead 2
13-----Plastic bead 3
14-----Triangle purple plastic
x+“Half violin”
x+“Irregular elongated rectangle”
x+“Irregular opacity”
x+“Irregular opacity”
x+“Linear lucency”
x+“Irregular lucency”
x+“Irregular opacity”

Open in a separate window

Rad: Radiologist; +: Positive identification of object denoted; x: No object/false positive.

Open in a separate window

Images of foreign objects. A: Color photograph before embedding in gelatin; B: Color photograph after embedding in gelatin; C: Plain X-ray taken with objects embedded and placed on water-equivalent phantom.

DISCUSSION

This is the first published study assessing visibility of non-metallic objects using an inexpensive, simple, easily reproducible model that represents a child’s body density. Gelatin slabs have variable distribution of embedded air bubbles that may help simulate the presence of fat in the child’s body. The excellent agreement found in our study among experienced radiologists validates (face value) the model. If the accuracy and utility of our model is confirmed in larger studies, it could potentially be used to predict the visibility of FB in children. The fact that some objects could not be seen by any radiologist suggests that such an object may not be visible if ingested by children. More than half of the items were either not detected or detected inconsistently, raising the potential for unnecessary diagnostic XR or missed opportunity for intervention in patients. Toy ingestions represent almost 7% of all phone calls to poison control in children less than 5 years of age in the United States[1]. Some of the most popular toys used by children such as Legos™ could not be visualized by any radiologist. Regardless of whether a given ingested object presents significant risk, parental (and primary care provider) anxiety often leads to repeated patient evaluation.

The results of our study underscore the need for an easily accessible FB registry denoting XR visibility. The creation of such a registry could be instrumental in helping radiologists and emergency room physicians in diagnosis and management. Enhancing confidence in diagnosing the presence of an ingested FB could facilitate the physician’s medical plan and alleviate parental anxiety. The European Registry on Upper Aerodigestive Tract Foreign Body Injuries in Children (Susy Safe)[23] serves as a successful model with data input at the point of care by all member institutions. Susy Safe data has demonstrated the need for ongoing collection of information to identify modifiable risk factors in toy design[24] as well as the ongoing necessity of integrative preventative strategies[25,26]. Our proposed registry should be internet-accessible and include standardized data fields for radiographic characteristics of FB that are lacking in the Susy Safe registry.

Imaging modalities other than XR for detection and characterization of ingested foreign bodies are rarely used in clinical and research settings. Ultrasonographic techniques show promise and are radiation free[27], but they require a skilled technician at the point of care and specialized equipment. Other modalities including contrast XR, computed tomography[28], and magnetic resonance imaging (MRI) may be helpful in specific circ*mstances, but involve increased radiation exposure (except MRI), cost, and complexity.

Limitations of this study include the utilization of a model, rather than clinical data, and a small panel of objects subjected to radiographic identification. However, the use of a model simulating the child’s body helps circumvent the ethical considerations of obtaining repeated XR in children.

Our study demonstrates the potential inability to detect ingested non-metallic FBs in children using XR. It also shows that while agreement among radiologists is excellent, some objects are inconsistently or never detected. Some of the objects not detected are common, present in many households and easily accessible to children. We propose a model to assess the visibility of non-metallic FB by XR. Future studies including a larger pool of objects should be conducted to confirm our findings. The creation of an easily accessible FB database should be considered.

COMMENTS

Background

Foreign body (FB) ingestion in children is common. X-ray (XR) is a simple diagnostic test that may assist with identification and localization of ingested FB. However, it is not clear whether non-metal objects are radiopaque. This leads to significant difficulty in utilizing XR to guide treatment decisions.

Research frontiers

The study proposes a simple, clinically relevant imaging model that could be used to predict FB visibility in children.

Innovations and breakthroughs

Despite high frequency of FB ingestion and importance of diagnostic radiography in guiding therapy, there are only case reports describing ability of XR to detect specific non-metallic FBs. The study assesses non-metallic FB identification by XR.

Applications

A similar model can be used at the point of care to predict XR visibility of an ingested foreign body. This could limit unnecessary procedures, or more rapidly and accurately indicate whether endoscopic or surgical retrieval is needed.

Peer review

The authors studied the utility of XR in identifying non-metallic foreign bodies and inter-radiologist agreement in identifying non-metal foreign body using custom designed water equivalent phantoms, and concluded that the potential inability to detect ingested non-metallic foreign bodies in children using XR. This paper is well-written and has interesting and important findings.

Footnotes

P- Reviewers: Alessandro I, ChoiYH, Viswanatha B, Watanabe T S- Editor: Zhai HH L- Editor: A E- Editor: Wu HL

References

1. Bronstein AC, Spyker DA, Cantilena LR, Green JL, Rumack BH, Dart RC. 2010 Annual Report of the American Association of Poison Control Centers’ National Poison Data System (NPDS): 28th Annual Report. Clin Toxicol (Phila) 2011;49:910–941. [PubMed] [Google Scholar]

2. Louie JP, Alpern ER, Windreich RM. Witnessed and unwitnessed esophageal foreign bodies in children. Pediatr Emerg Care. 2005;21:582–585. [PubMed] [Google Scholar]

3. Wright CC, Closson FT. Updates in pediatric gastrointestinal foreign bodies. Pediatr Clin North Am. 2013;60:1221–1239. [PubMed] [Google Scholar]

4. Chiu YH, Hou SK, Chen SC, How CK, Lam C, Kao WF, Yen DH, Huang MS. Diagnosis and endoscopic management of upper gastrointestinal foreign bodies. Am J Med Sci. 2012;343:192–195. [PubMed] [Google Scholar]

5. Kay M, Wyllie R. Pediatric foreign bodies and their management. Curr Gastroenterol Rep. 2005;7:212–218. [PubMed] [Google Scholar]

6. Takagaki K, Perito ER, Jose FA, Heyman MB. Gastric mucosal damage from ingestion of 3 button cell batteries. J Pediatr Gastroenterol Nutr. 2011;53:222–223. [PMC free article] [PubMed] [Google Scholar]

7. Hussain SZ, Bousvaros A, Gilger M, Mamula P, Gupta S, Kramer R, Noel RA. Management of ingested magnets in children. J Pediatr Gastroenterol Nutr. 2012;55:239–242. [PubMed] [Google Scholar]

8. Agrawal V, Joshi MK, Jain BK, Gupta A. Plasticobezoar-another new entity for Rapunzel syndrome. Indian J Pediatr. 2009;76:229–230. [PubMed] [Google Scholar]

9. Counsilman CE, van Velzen MF. Subcutaneous emphysema after ingestion of a pencil. Arch Dis Child. 2011;96:147. [PubMed] [Google Scholar]

10. Fujiwara T, Nishimoto S, Kawai K, f*ckuda K, Okuyama H, Kakibuchi M. Exacerbation of oesophageal stenosis by accidental ingestion of tape. J Plast Surg Hand Surg. 2012;46:207–208. [PubMed] [Google Scholar]

11. Glover P, Westmoreland T, Roy R, Sawaya D, Giles H, Nowicki M. Esophageal diverticulum arising from a prolonged retained esophageal foreign body. J Pediatr Surg. 2013;48:e9–12. [PubMed] [Google Scholar]

12. Golffier C, Holguin F, Kobayashi A. Duodenal perforation because of swallowed ballpoint pen and its laparoscopic management: report of a case. J Pediatr Surg. 2009;44:634–636. [PubMed] [Google Scholar]

13. Rameau A, Anand SM, Nguyen LH. Ballpoint pen ingestion in a 2-year-old child. Ear Nose Throat J. 2011;90:E20–E22. [PubMed] [Google Scholar]

14. Gowda D, Familua O, Sathyanarayana N. Toothbrush ingestion leading to laparotomy. Am Surg. 2010;76:E193–E194. [PubMed] [Google Scholar]

15. Hon KL, Chu WC, Sung JK. Retropharyngeal abscess in a young child due to ingestion of eel vertebrae. Pediatr Emerg Care. 2010;26:439–441. [PubMed] [Google Scholar]

16. Kappadath SK, Clarke MJ, Stormer E, Steven L, Jaffray B. Primary aortoenteric fistula due to a swallowed twig in a three-year-old child. Eur J Vasc Endovasc Surg. 2010;39:217–219. [PubMed] [Google Scholar]

17. Mahajan M, Gandhi V, Nagral A. An unusual cause of vomiting in a child. BMJ Case Rep. 2011;2011 [PMC free article] [PubMed] [Google Scholar]

18. Moon JS, Bliss D, Hunter CJ. An unusual case of small bowel obstruction in a child caused by ingestion of water-storing gel beads. J Pediatr Surg. 2012;47:E19–E22. [PubMed] [Google Scholar]

19. Zamora IJ, Vu LT, Larimer EL, Olutoye OO. Water-absorbing balls: a “growing” problem. Pediatrics. 2012;130:e1011–e1014. [PubMed] [Google Scholar]

20. Ortmann LA, Jaeger MW, James LP, Schexnayder SM. Coma in a 20-month-old child from an ingestion of a toy containing 1,4-butanediol, a precursor of gamma-hydroxybutyrate. Pediatr Emerg Care. 2009;25:758–760. [PubMed] [Google Scholar]

21. Ragazzi M, Delcò F, Rodoni-Cassis P, Brenna M, Lavanchy L, Bianchetti MG. Toothpick ingestion causing duodenal perforation. Pediatr Emerg Care. 2010;26:506–507. [PubMed] [Google Scholar]

22. Stringel G, Parker M, McCoy E. Vinyl glove ingestion in children: a word of caution. J Pediatr Surg. 2012;47:996–998. [PubMed] [Google Scholar]

23. Gregori D. The Susy Safe Project. A web-based registry of foreign bodies injuries in children. Int J Pediatr Otorhinolaryngol. 2006;70:1663–1664. [PubMed] [Google Scholar]

24. de Koning T, Foltran F, Gregori D. Fostering design for avoiding small parts in commonly used objects. Int J Pediatr Otorhinolaryngol. 2012;76 Suppl 1:S57–S60. [PubMed] [Google Scholar]

25. Foltran F, Gregori D, Passàli D, Bellussi L, Caruso G, Passàli FM, Passàli GC. Toys in the upper aerodigestive tract: evidence on their risk as emerging from the ESFBI study. Auris Nasus Larynx. 2011;38:612–617. [PubMed] [Google Scholar]

26. Foltran F, Passali FM, Berchialla P, Gregori D, Pitkäranta A, Slapak I, Jakubíková J, Franchin L, Ballali S, Passali GC, et al. Toys in the upper aerodigestive tract: new evidence on their risk as emerging from the Susy Safe Study. Int J Pediatr Otorhinolaryngol. 2012;76 Suppl 1:S61–S66. [PubMed] [Google Scholar]

27. Piotto L, Gent R, Kirby CP, Morris LL. Preoperative use of ultrasonography to localize an ingested foreign body. Pediatr Radiol. 2009;39:299–301. [PubMed] [Google Scholar]

28. Luk WH, Fan WC, Chan RY, Chan SW, Tse KH, Chan JC. Foreign body ingestion: comparison of diagnostic accuracy of computed tomography versus endoscopy. J Laryngol Otol. 2009;123:535–540. [PubMed] [Google Scholar]

Articles from World Journal of Clinical Pediatrics are provided here courtesy of Baishideng Publishing Group Inc

X-ray detection of ingested non-metallic foreign bodies (2024)

FAQs

Will swallowed plastic show up on X-ray? ›

The visibility of plastic is variable on both conventional radiography and computed tomography, depending on composition, but all types of plastic are well visualized on ultrasound.

Will Lego show up on X-ray? ›

Despite radiographic invisibility of plastic objects, distinctive arrangement of radiolucent densities when air is trapped inside a Lego block offers a diagnostic clue to justify further invasive procedures.

What is the best X-ray for a foreign body ingestion? ›

Imaging Studies

Most ingested foreign bodies are radiopaque (in contrast to inhaled foreign bodies which usually are radiolucent). If the swallowed object may be radiopaque, a single frontal radiograph that includes the neck, chest, and entire abdomen is usually sufficient to locate the object.

Can you see foreign body on X-ray? ›

Although routine radiography is the preferred imaging modality for the initial workup, several types of soft-tissue foreign bodies are not radiopaque and therefore remain undetected. Because a retained foreign body may cause infection and inflammation, detection and removal are imperative [1].

Will I be OK if I swallowed a piece of plastic? ›

Depending on the size of the plastic piece you swallowed, if it does not cause any discomfort when it went down your throat, you will most likely pass it out when you go to the toilet. On the other hand, if the plastic piece is sharp, it may damage your gut lining and cause internal bleeding.

How long does it take to pass a piece of plastic that was accidentally swallowed? ›

What You Should Expect: Swallowed objects almost always make it to the stomach. Once there, they usually travel safely through the intestines. They are passed in a normal stool in 2 or 3 days.

Does silicone show up on xray? ›

Silicone is a chemically inert, biocompatible, hypoallergic, and stable material. Because of its properties, it's commonly used in medical devices such as catheters and implants. On x-rays, silicone appears radiolucent. This makes it hard to differentiate it from soft tissues.

Can you see hair on an xray? ›

Artifacts from clothing, jewelry and hair are occasionally spotted on radiographs. Lucent artifacts like skin fold and hair are difficult to spot compared to radiopaque artifacts.

Do rocks show up on xray? ›

X-ray computed tomography (X-ray CT) has been widely used in the earth sciences, as it is non-destructive method for providing us the three-dimensional structures of rocks and sediments.

What is the investigation of choice for foreign body ingestion? ›

For the purpose of initial diagnosis, radiographs can confirm the location, size, shape, and num- ber of ingested foreign bodies and can help to exclude aspirated objects [5]. Radiographs identify most foreign bodies, especially if the object is likely to be radiopaque [13].

How do you detect a foreign body? ›

Often, a foreign body can be seen on x-rays of the abdomen and sometimes of the chest. Sometimes other imaging tests, such as computed tomography (CT), may be done to help identify and locate the foreign body. Usually, endoscopy.

What is the most common location for an aspirated foreign body? ›

Of aspirated foreign bodies, 80-90% become lodged in the bronchi. In adults, bronchial foreign bodies tend to be lodged in the right main bronchus because of its lesser angle of convergence compared with the left bronchus and because of the location of the carina left of the midline.

Will LEGO show up on CT? ›

Results: The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %).

What to do if kid swallowed LEGO? ›

Most children have no symptoms after swallowing an object, and the object will not cause any problems. Occasionally, the swallowed object can become stuck in the oesophagus. Take your child to a doctor or hospital emergency department if they have: trouble swallowing food.

Can you scan LEGO pieces? ›

Spread out your bricks and take a photo of them. The app will scan the photo, identifying and counting the details. 2. Decide what to build.

Top Articles
Latest Posts
Article information

Author: Velia Krajcik

Last Updated:

Views: 6022

Rating: 4.3 / 5 (54 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Velia Krajcik

Birthday: 1996-07-27

Address: 520 Balistreri Mount, South Armand, OR 60528

Phone: +466880739437

Job: Future Retail Associate

Hobby: Polo, Scouting, Worldbuilding, Cosplaying, Photography, Rowing, Nordic skating

Introduction: My name is Velia Krajcik, I am a handsome, clean, lucky, gleaming, magnificent, proud, glorious person who loves writing and wants to share my knowledge and understanding with you.